YAN Wei-ping1, HUANG Jing-li1, LI Jun1, et al. CALCULATION OF MINIMUM WALL TEMPERATURE AND INLET AIR TEMPERATURE OF REGENERATIVE AIR HEATER[J]. Thermal power generation, 2007, (4): 47-49.
YAN Wei-ping1, HUANG Jing-li1, LI Jun1, et al. CALCULATION OF MINIMUM WALL TEMPERATURE AND INLET AIR TEMPERATURE OF REGENERATIVE AIR HEATER[J]. Thermal power generation, 2007, (4): 47-49. DOI: 10.19666/j.rlfd.2007.04.011.
The calculation formula of the heating surface metal temperature for hot section of the regenerative air heater has been deduced from the heat transfer principle
the problems existing in calculation of minimum wall temperature being analysed
and methods for improvement being put forward.For differently designed regenerative air heaters of two 200 MW boilers in one coal-fired power plant
the acid dew point temperature
the minimum wall temperature of hot section
and the inlet air temperature have been calculated and compared.The proposed method and results can be used as reference for choosing the reasonable inlet air temperature and optimizing the designed proportion of cold and hot sections of the heating surface.