ANAMSIS OF TUBE-WALL TEMPERATURE FOR SUPERHEATER WITH DIVIDING PANEL UNDER OFF -DESIGN CONDI-TION OF 600 MW UNIT'S BOILER[J]. Thermal power generation, 2006, (12): 64-66.
ANAMSIS OF TUBE-WALL TEMPERATURE FOR SUPERHEATER WITH DIVIDING PANEL UNDER OFF -DESIGN CONDI-TION OF 600 MW UNIT'S BOILER[J]. Thermal power generation, 2006, (12): 64-66. DOI: 10.19666/j.rlfd.2006.12.021.
Through three-dimensional tube - wall temperature calculation of the front panel superheater for a tangential firing boiler of 600 MW unit under six operating con-ditions
namely BMCR
BRL
100 % ECR
75 % sliding pressure. 50 % sliding pressure
and cut - off of the high - pressure beater
a typical three - dimensional tube - wall temperature distribution of the front panel superheater
and positions at which the highest tube - wall temperature being occurred
as well as values of the highent tube - wall temperature under various operating conditions have been obtained. Based on results of calculating the tubewall temperature of the superheater with dividing panel
a optimi-zing design scheme has been put forward for designing the superheater and selecting the materials used.