GUO Qing-feng. ANALYSIS AND REMEDY OF BURST-LEAKAGE OF "FOUR KINDS OF TUBE" IN BOILERS OF SHIMEN POWER PLANT[J]. Thermal power generation, 2006, (12): 31-33.
GUO Qing-feng. ANALYSIS AND REMEDY OF BURST-LEAKAGE OF "FOUR KINDS OF TUBE" IN BOILERS OF SHIMEN POWER PLANT[J]. Thermal power generation, 2006, (12): 31-33. DOI: 10.19666/j.rlfd.2006.12.010.
The situation of burst - leakage concerning "four kinds of tube" in boilers of 2×300 MW units in first -phase project of Shimen Power Plant has been analysed. It is believed that the main causes resulting in burst - leakage to be as follows : defects in quality of 102 steel t worn - outj over - temperaturei blowing damage by steam soot blower ; scaling caused by water quality; defects in manufacture and installation; etc. For these
corresponding remedial meausres have been put forward. After implementation
the safety and reliability of "four kinds of tube" in boilers have been enhanced