YU Ting-fang, WANG Xia. EXERGY ANALYSIS OF COMBINED CYCLE POWER-GENERATION SYSTEM INTEGRATING PARTIAL COAL GASSIFICATION WITH FLUIDIZED BED COMBUSTION TECHNOLOGY[J]. Thermal power generation, 2006, (3): 1-4.
YU Ting-fang, WANG Xia. EXERGY ANALYSIS OF COMBINED CYCLE POWER-GENERATION SYSTEM INTEGRATING PARTIAL COAL GASSIFICATION WITH FLUIDIZED BED COMBUSTION TECHNOLOGY[J]. Thermal power generation, 2006, (3): 1-4. DOI: 10.19666/j.rlfd.2006.03.001.
Calculation and analysis of exergy loss for a combined cycle power-generation system of adopting pressurized fluidized bed combustion (PFBC) and adopting atmospheric fluidized bed combustion (AFBC) have been carried out
the exergy loss coefficient and the exergy efficiency in various links of said power-generation system being given
pointing out the combustion chamber and the steam generation system to be the weak links of the said power-generation system
the total sum of exergy loss coefficeient for both of them to be about 30%~35%. Further more
some measures for reducing exergy loss and for enhancing efficiency of the power-generation system of this kind have been put forward.