HUANG Qiang. COMPREHENSIVE CONTROL OF DUST POLLUTION IN COAL HANDLING SILO BAY OF POWER PLANT[J]. Thermal power generation, 2006, (1): 61-62. DOI: 10.19666/j.rlfd.2006.01.019.
电厂煤仓间粉尘的综合治理
摘要
对安庆石油化工总厂热电厂煤仓间粉尘污染的原因进行分析
并介绍粉尘综合治理方法及新型LZZDP扁布袋除尘器的除尘机理和安装使用情况。实践证明
所采用的治理方案是成功的
治理后煤仓间空气含尘量常维持在13mg/m3以下。
Abstract
Causes leading to dust pollution in coal silo bay of thermal power plant under Anqing PetroChemical General Factory have been analysed
the comprehensive control method
as well as dust removal mechanism and situation of installing and utilizing new type LZZDP flat bag filter being presented. Practice shows that the control scheme newly adopted to be successful. After implementation
the dust content in atmospheric air of the silo bay to be usually maitained at less than 13 mg/m3.