EVALUATION OF STRUCTURAL PERFORMANCE FOR 12Cr1MoV STEAM CONDUIT FROM BOILER OF UNIT NO4 IN JINZHUSHAN POWER PLANT[J]. Thermal power generation, 2005, (12): 93-95.
EVALUATION OF STRUCTURAL PERFORMANCE FOR 12Cr1MoV STEAM CONDUIT FROM BOILER OF UNIT NO4 IN JINZHUSHAN POWER PLANT[J]. Thermal power generation, 2005, (12): 93-95. DOI: 10.19666/j.rlfd.2005.12.031.
Comprehensive analysis and evaluation of the structural damage and servicelife state for 12 Cr1MoV steam conduit from boiler of unit no4 in Jinzhushan Power Plant have been carried out by using many methods
such as analysis of chemical composition
elongation test under normal atmosphere temperature
metallurgical and electronic microscopic analysis
creep damage observation
endurance strength test under high temperature etc.. Test results show that the spheroidizing degree of metallurgical structure appeared at the elbow bent of said steam conduit after operation of 151609h to be serious
the creep damage approaches 3rd degree
and obvious reduction of tensile strength under normal atmosphere temperature and of endurance strenoth under high temperature. In continuous utilization of said steam conduit
supervision should be strengthened for its elbow bent