TECHNICAL RETROFIT FOR ENERGYSAVING OF 32SA19A TYPE CIRCULATING WATER PUMPS IN WENHULIANG POWERGENERATION COMPANY[J]. Thermal power generation, 2005, (9): 59-62.
TECHNICAL RETROFIT FOR ENERGYSAVING OF 32SA19A TYPE CIRCULATING WATER PUMPS IN WENHULIANG POWERGENERATION COMPANY[J]. Thermal power generation, 2005, (9): 59-62. DOI: 10.19666/j.rlfd.2005.09.016.
Directing against problems of the designed parameters of 32SA19A type circulatingwater pump being not properly matched with the circulating water system
low efficiency in operation
and high energy consumption etc.
a retrofitting scheme has been put forward. The performance test results and economic benefits after retrofitting have been analysed.