HE Wang-fei, YE Gang. CAUSE ANALYSIS OF WATER-WALL TUBE BURST AND LEAKAGE FOR A 2100t/h BOILER[J]. Thermal power generation, 2004, (8): 71-72. DOI: 10.19666/j.rlfd.2004.08.023.
2100t/h锅炉水冷壁管爆漏原因分析
摘要
针对某火电厂 2 10 0t/h锅炉水封槽部位水冷壁管爆漏问题
通过宏观检验
化学成分、力学性能及金相组织分析等手段对其原因进行了分析
认为该爆管属于应力拉裂所致。对此
提出了相应的预防措施和建议。
Abstract
Directing against the problems of water-wall tube burst and leakage in seal-water tank for a 2100 t/h boiler in one thermal power plant
the cause analysis has been carried out through several means
such as macroscopic examination
chemical composition analysis
mechanical performance analysis
and metallurgical structure analysis etc.. It is considered that the tube burst belongs in stress pull-breakage
and corresponding preventive measures and recommendations having been put forward for the said failures.