LI Xujun, KONG jian. ALLOCATION AND CAPACITY SELECTION OF BYPASS SYSTEM FOR LOCALIZED 600MW UNITS[J]. Thermal power generation, 2004, (5): 1-4. DOI: 10.19666/j.rlfd.2004.05.001.
国产化600MW超临界机组旁路系统的配置和容量选择
摘要
介绍了目前国内引进的超临界机组旁路系统现状以及机组常用的旁路系统型式
分析了机组甩负荷带厂用电运行的功能与旁路系统的关系。针对国产化 6 0 0MW超临界机组
提出了其旁路系统应具有的功能和旁路系统容量选择应考虑的因素。
Abstract
Status quo of bypass system for supercritical units imported from abroad
as well as the types of bypass system commonly used at home
have been described. The relationship of function concerning unit to reject load and only to supply service power for auxiliaries in the plant with the bypass system being analysed. Directing against the bypass system of localized 600MW units
the funetions having to had with the bypass system
as well as factors having to be considered for capacity selection of the bypass system have been put forward.