HUANG Tao. RETROFITTING SCHEME FOR REDUCING TEMPERATURE OF THE SERVOMOTOR OF HIGHPRESSURE GOVERNING VALVE ON A 300MW STEAM TURBINE[J]. Thermal power generation, 2004, (4): 73-75.
HUANG Tao. RETROFITTING SCHEME FOR REDUCING TEMPERATURE OF THE SERVOMOTOR OF HIGHPRESSURE GOVERNING VALVE ON A 300MW STEAM TURBINE[J]. Thermal power generation, 2004, (4): 73-75. DOI: 10.19666/j.rlfd.2004.04.022.
300MW汽轮机组高压调节汽门油动机降温改造方案
摘要
大坝发电厂 3号、4号汽轮机组投产以来高压调节汽门油动机的油缸温度一直偏高
经常发生油缸上部密封圈泄漏
压力油烧结积碳
油质变差
伺服阀频繁故障等问题
对此提出了改造方案
实施后取得显著效果。
Abstract
The temperature of servomotor's oil cylinder concerning the highpressure governing valve of a 300MW unit NO.3 in Daba Power Plant is somewhat higher from the begining of putting into operation right up to now
some problems
such as upper seal leakage of the oil cylinder
agglomerition and carbon deposition of the pressure oil
deterioration of the oil quality
as well as frequent failure of the servo valve etc.