ANALYSIS FOR INFLUENCE OF FURNACE POLLUTION AND PURGING UPON OPERATION OF CONVECTIVE HEATING SURFACE[J]. Thermal power generation, 2004, (3): 27-30. DOI: 10.19666/j.rlfd.2004.03.009.
The flue gas temperature at each point in the outlet of furnace and in convective flue gas conduit are varied according to different degree of furnace pollution on the heating surface in ulility boilers
infuencing upon heat exchange of the furnace and of the convective heating surface thereafter. Directing against a 1035 t/h boiler
the variation regularity of absorbed heat on each heating surface after changing ash pollution coefficient in the furnace has been calculated
theoretical analysis model being established. Combining with data of practical sootblowing operation of the boiler
the influence of furnace pollution variation upon operation of superheater and reheater system has been deeply analysed
having certain reference value for working out optimal sootblowing strategy for furnace of boilers.