MATRIX CALCULATION OF CONVERSION λ FOR EQUIVALENT HEATREDUCTION UNDER CONSTANT HEAT QUANTITY[J]. Thermal power generation, 2004, (1): 15-17. DOI: 10.19666/j.rlfd.2004.01.004.
alWhen an equivalent heatreduction under constant heat quantity is used as partial analysis
it is necessary to change workdone obtained into equivalent heareduction variation of the live steam through conversion factor λ
and then the relative variation of economic index can be evaluated. Combining with qγτ matrix equation
the calculation models of conversion factor corresponding to three kinds of auxiliary steamwater entering into and outgoing from the thermal system (i、e. from steam side or water side of the heaters
or with pure heat quantity) have been established
perfecting the application system of equivalent heatredution under constant quantity. Taking a homemade N 125135/550/550 unit as example
the adaptability of the models has been discussed.