CAUSE ANALYSIS OF SHAFT-PACKING LEAKAGE AND UNSMOOTHLY CLOGGING OF ROTARY DIAPHRAGM FOR C12-35/10 TYPE STEAM TURBINE, AS WELL AS RETROFITTING THEREOF[J]. Thermal power generation, 2003, (8): 67-68.
CAUSE ANALYSIS OF SHAFT-PACKING LEAKAGE AND UNSMOOTHLY CLOGGING OF ROTARY DIAPHRAGM FOR C12-35/10 TYPE STEAM TURBINE, AS WELL AS RETROFITTING THEREOF[J]. Thermal power generation, 2003, (8): 67-68. DOI: 10.19666/j.rlfd.2003.08.024.
Troublesome problems of C12-35/10 type steam turbine No.3 in the first-phase project of thermal power plant under Shanxi Branch Company of China Aluminium Co Ltd
such as large steam leakage from shaft-packing
unsmoothly clogging of rotary diaphragm
high pressure appeared before the rotary diaphragm and after the secondary pressure stage under pure condensing operation
as well as the unit can not be operating under full load etc.
have been analysed
the reasonable retrofitting scheme being put forward