APPLICATION OF NSH TYPE ON-LINE NORMAL PRESSURE CALIBRATIOR FOR SAFETY VALVES IN YAHEKOU POWER PLANT[J]. Thermal power generation, 2003, (7): 57-60. DOI: 10.19666/j.rlfd.2003.07.019.
The situation of using NSH type on-line normal pressure calibrator for safety valves in Yahekou Power Plant to check DRESSOR safety valves of boilers has been presented
and the system structure and operatinal steps of said calibrator being briefed. Based on the designed accuracy of sampler
sensor and amplifer selected for the said calibrator
the measurement error of seat-leaving pressure for the testing system has been analysed. Through veriffcation of real-trip by raising pressure
it is found that the repeatability error and the measuring error of said calibrator aren’t all exceeding 1%
satisfying the requirements of National Standard and ASME Standard. practice shows
on the basis of comparison with traditional methods
the said calibrator has high accuracy
less time-consurming
and good security. The performance testing and seatleaving pressure setting of a single safety valve can be completed only in 10min under normal operation condition of the unit