Luo Peiliu. CAUSE ANALYSIS OF NEEDING REPEAT REGENERATION IN THE PRIMARY DESALTING SYSTEM[J]. Thermal power generation, 2003, (6): 68-69. DOI: 10.19666/j.rlfd.2003.06.022.
一级除盐系统重复再生原因分析
摘要
分析沙角发电C厂化学水处理一级除盐系统经常出现重复再生才能投入运行的情况
认为阳床的阳离子交换树脂再生时受到再生剂中铁的污染
经更换阳树脂和采用优质的再生剂后问题得以解决
Abstract
Events often occurred in the primary desalting system of chemical water treatment facility
which can be put into operation again only after repeat regeneration
at Shajiao C Power Plant have been analysed. It is considered that the cation exchange resin in the cation bed was polluted by iron contained in regenerative agent during the time of regeneration. After replacing cation exchange resin and adopting top quality regenerative agent