ELIMINATION OF GAS AND AIR DUCTS' VIBRATION AS WELL AS VIBRATION DUE TO FANS' FOULING FOR BOILERS OF 100 MW UNIT[J]. Thermal power generation, 2003, (6): 66-67.
ELIMINATION OF GAS AND AIR DUCTS' VIBRATION AS WELL AS VIBRATION DUE TO FANS' FOULING FOR BOILERS OF 100 MW UNIT[J]. Thermal power generation, 2003, (6): 66-67. DOI: 10.19666/j.rlfd.2003.06.021.
In view of phenomena concerning gas and air ducts’ vibration as well as vibration due to fans’ fouling in Niangziguan Power Plant
causes leading to occurance of said phenomena have been analysed through frequency spectrum test and hot state test. It is considered that the main causes leading to said vibration are: out-of-matching between forced draft fan and the resistance of draft air pipeline
bad quality of fixing the air ducts
and ash deposition on the bladed disc of induced draft fan
etc. After retrofitting the forced draft fan as 5-53 type high-effective one
and the induced draft fan as 4-6B type fan with straight-plate blades