Huo Dongfang. KINDS AND TECHNICAL FEATURES OF THE STARTING-UP SYSTEM FOR SUPERCRITICAL ONCE-THROUGH BOILERS[J]. Thermal power generation, 2003, (5): 31-34.
Huo Dongfang. KINDS AND TECHNICAL FEATURES OF THE STARTING-UP SYSTEM FOR SUPERCRITICAL ONCE-THROUGH BOILERS[J]. Thermal power generation, 2003, (5): 31-34. DOI: 10.19666/j.rlfd.2003.05.010.
Common kinds and technical features of the starting-up system for once-through boilers have been analysed and compared. The starting-up system with start-up drain heat exchange and recirculation has good behavior under extremely low load operation and for frequent start-up
being suitable for operation under medium load and for two-shift operation; The flashing type has bad behavior under low load operation and for frequent start-up
being suitable for power plants with basic load. There are unique advantages and obvious deficiencies in practical operauion of each kind of starting-up system. Hence
it is necessary to comprehensively consider the factors
such as technical features
capital investment
and operation mode of power plants etc. for selecting the suitable type of starting-up system.