A STUDY ON DETECTION TECHNIQUE REGARDING TRACE AMOUNT OF SODIUM IONS IN HIGHLY PURE WATER[J]. Thermal power generation, 2003, (2): 56-57. DOI: 10.19666/j.rlfd.2003.02.019.
高纯水中痕量钠离子检测技术的研究
摘要
对于浓度为 5 μg/L以下的痕量钠离子
可用二阶微分火焰光谱法测定。该方法快速、简便、准确。配合使用性价比较好的国产智能分析仪
其有望得到推广和普及
Abstract
For trace amount of sodium ions below density of 5μg/L
detection can be carried out by using second derivative flame spectroscopic method. This method is fast
being simple and easy to use
and having high accuracy. It is hopeful to spread and popularize this method by cooperating with utilization of home-made intelligent analysers having better performance/cost ratio.