AN APPROACH TO THE CAUSES OF WATER-WALL SLAGGING FOR A 410t/h PULVERIZED-COAL FIRED BOILER AND COUNTERMEASURES FOR SOLVING THE PROBLEM[J]. Thermal power generation, 2003, (1): 34-36.
AN APPROACH TO THE CAUSES OF WATER-WALL SLAGGING FOR A 410t/h PULVERIZED-COAL FIRED BOILER AND COUNTERMEASURES FOR SOLVING THE PROBLEM[J]. Thermal power generation, 2003, (1): 34-36. DOI: 10.19666/j.rlfd.2003.01.010.
一台410t/h燃煤锅炉水冷壁结渣原因探讨及解决对策
摘要
北京国华电力有限责任公司热电分公司 1号锅炉运行中结渣严重
对此从燃料特性、锅炉结构、炉内空气动力结构、运行状况等方面进行了分析
探讨了其结渣的原因
并提出了相应的解决措施
Abstract
Serious slagging had occurred in operation of boiler No.1 in The Heat And Electricity Generation Branch Company under Beijing Guohua Electric Power Co. Ltd. Hence
analysis has been carried out from severial aspects
such as fuel property
boiler structure
configuration of air flow field in the furnace
and its operational situation etc.
An approach to the causes of slagging has been made
and corresponding measures for solving the said problem have been put forward.