The causes of frequent water-wall leakages induced from tube-burst on 1025t/h UP once-through boiler have been analyzed. It is considered that the main causes of said problem are defects existing in boiler design and operation
such as strong thermal sensibility of water-wall tubes
great heat deviation in the furnace
unjustifiable structure of rigid beams and furnace hermetization etc.. Hence
corresponding measures for retrofitting have been put forward.