POWER CONSUMPTION ANALYSIS OF NORMAL WET TYPE AND CT-121 TYPE FGD PROCESSES[J]. Thermal power generation, 2002, (6): 46-49. DOI: 10.19666/j.rlfd.2002.06.015.
常规湿法与CT─121脱硫的电耗分析
摘要
分析了常规湿式石灰石 /石膏法脱硫技术和日本千代田公司CT 12 1脱硫技术的工艺差别和脱硫性能
其工艺差别主要在脱硫塔部分和与此有关的设备。对 2种工艺的电耗进行了分析研究
Abstract
The technological difference and desulfurization performance of normal wet type lime-stone/gypsum flue gas desulfurization (FGD) and CT-121 type FGD process of Japanese Chiyota Company are analysed
the technological difference between the two processes is mainly existing in the part of desulfurization tower and its related facilities. Analysis and study of the power consumption regarding the two FGD processes has also been carried out.