LIU Ran-xing. IMPROVEMENT OF OPERATIONAL PERFORMANCE FOR HG2008 TYPE DOMESTIC COAL-FIRED BOILERS[J]. Thermal power generation, 2002, (2): 44-46. DOI: 10.19666/j.rlfd.2002.02.013.
such as temperature excursion of superheated steam an d reheated steam
unreasonable design of heating surface
higher resistance in superheater system
and defects of burner-swinging actuator etc. occurred in operation of four HG2008 type coal-fired boilers on active service for 600MW units manufactured by Harbin Boiler Factory have been summarized
and corresponding measures for improvement have been put forward
providing for design and operation optimization of homemade large capacity coal-fired boilers with beneficial experiences.