1. 高坝发电厂
2. 国家电力公司热工研究院,四川,内江,641006
3. ,陕西,西安,710032
纸质出版:2001
移动端阅览
张文清, 张敏. 内江高坝发电厂410t/h循环流化床锅炉技术改进[J]. 热力发电, 2001,(6):34-35.
TECHNICAL RETROFIT OF A 410t/h CFB BOILER AT GAOBA POWER PLANT OF NEIJIANG CITY, SICHUAN PROVINCE[J]. Thermal power generation, 2001, (6): 34-35.
张文清, 张敏. 内江高坝发电厂410t/h循环流化床锅炉技术改进[J]. 热力发电, 2001,(6):34-35. DOI: 10.19666/j.rlfd.2001.06.009.
TECHNICAL RETROFIT OF A 410t/h CFB BOILER AT GAOBA POWER PLANT OF NEIJIANG CITY, SICHUAN PROVINCE[J]. Thermal power generation, 2001, (6): 34-35. DOI: 10.19666/j.rlfd.2001.06.009.
介绍四川内江高坝发电厂 4 10t/h引进循环流化床锅炉投运 4年来出现的主要问题及对流化风管、冷却水、冷却水箱、二次风机、一次风机、旋风分离器回料腿非金属膨胀节、飞灰再循环系统、上二次风口、底灰冷却器等进行的改进情况。这些改进与完善
对循环流化床锅炉的设计、运行有一定的实际参考价值。
The troublesome problems occurred in four years from putting an imported title boiler into operation are presented
and retrofit of its components
such as fluidizing air pipes
cooling water pipes
cooling water tank
secondary air fan
primary air fan
non-metallic expansion joints on feed-back leg of cyclonic-separater
fly ash recirculating system
upper opening of secondary air
bottom ash cooler etc.
is described. It is considered to have definite value for reference in design and operation of CFB boilers.