ANALYSIS ON THE PERFORMANCE OF COMPOSITE HEAT-ACCUMULATION AND POWER-GENERATION TECHNOLOGY IN THERMAL POWER PLANT[J]. Thermal power generation, 2001, (5): 41-44.
ANALYSIS ON THE PERFORMANCE OF COMPOSITE HEAT-ACCUMULATION AND POWER-GENERATION TECHNOLOGY IN THERMAL POWER PLANT[J]. Thermal power generation, 2001, (5): 41-44. DOI: 10.19666/j.rlfd.2001.05.014.
With the increasing difference between Peak and valley loads in the power network
the needs of peak-regulation in the power network are becoming increasingly prominent
hence
the feasibility study for implementing the concrete scheme of new technology for composite heat-accumulation and power-generation in thermal power plant has been carried out. Taking the steamturbine-generator set of 600MW in a domestic power plant as example
The peak-regulation unit of composite heat-accumulation and power-generation in a 600MW+120MW thermal power plant has been made up
the selection and determination of its constituents and main parameters having been analyzed and calculated. In terms of theory
the feasibility and reasonableness of said scheme have been verified.