As an important parameter of steam turbine governing system
the dead band property was generally taken from the static characteristic curve. The infection of all factors in governing system upon the said property has been analyzed
it has pointed out that the infection of slide-valve overclosing
friction and mechanical clearance upon the static characteristic is probabilistic
whereas the infection of oil hydraulic force is definite. The deference between static characteristic curve and static procedure curve has clearly been defined. It has pointed out that measuring up the dead band property by using maximum deference values from the up-and-down test static characteristic curve is not in perfection
and the crossing phenomenon at some points on the two curves being discussed as well