STUDY ON DOUBLE-CHANNEL CYCLONE-TYPE PULVERIZED COAL BURNER WITH INNER-POSITIONED FLAME-STABILIZING BODY AND ITS APPLICATION ON 410 t/h BOILER[J]. Thermal power generation, 2001, (2): 18-20.
STUDY ON DOUBLE-CHANNEL CYCLONE-TYPE PULVERIZED COAL BURNER WITH INNER-POSITIONED FLAME-STABILIZING BODY AND ITS APPLICATION ON 410 t/h BOILER[J]. Thermal power generation, 2001, (2): 18-20. DOI: 10.19666/j.rlfd.2001.02.006.
加内置稳焰体的双通道旋流煤粉燃烧器研究及其在410t/h锅炉上的应用
摘要
分析了加内置稳焰体的双通道旋流煤粉燃烧器的稳燃机理
给出了冷态模拟试验测量及研究结果
根据研究结果对山西霍州电厂 3号炉的旋流燃烧器进行了改造。工业试验结果表明
该燃烧器具有较好的稳燃性能
Abstract
The combustion-stabilizing mechanism of the title burner has been analyzed.The results of test
measurement and study of cold-state simulation have been given.Based on the results of study
the cyclone-type burner of boiler No 3 in Huozhou Power Plant
Shanxi province
has been retrofitted.The results of commercial experiments show
this kind of burner has better fire-stabilizing capability.