通过分析引风机轴承轴向不同位置振动幅值的差异和轴承刚度计算式
认为轴向振动高的原因是由于风机基础沉降引起的轴承单头扬起所致
给出了处理方法
Based on the analysis of vibration amplitudes at each axial positions and on the calculations of bearing rigidity of induced draft fan
it was found out that significant axial vibration was caused by bearing lifting due to foundation sinking of fan.