Abstract The condenser tube of Unit 1 of Datong No.2 Power Plant was found with big terminal temperature difference and low vacuum pressure during its operation.A technical proposal of cleaning by amino sulfonic acid and protection by potassium persulfate filming was proposed according to the result of a small-scale test.Described in this paper are the application process and effectiveness of this technology.It was proved by X-ray electron spectrometer inspection that a very good protection film was formed on the tube when this technology was used.The terminal temperature difference was decreased during operation from 13.0 C to 4.7 ℃
which reached A class grade (5 C) specified
and the coal consumption was decreased by 14.81 g/(kW.h).