ASSEMBLY DISTRIBUTED INTELLIGENT MONITORING SYSTEM AND ITS APPLICATION IN
FAILURE DIAGNOSIS OF BOILER WATERWALL.[J]. Thermal power generation, 1999, (2).
ASSEMBLY DISTRIBUTED INTELLIGENT MONITORING SYSTEM AND ITS APPLICATION IN
FAILURE DIAGNOSIS OF BOILER WATERWALL.[J]. Thermal power generation, 1999, (2). DOI: 10.19666/j.rlfd.1999.02.011.
Abstract This paper introduces a computer-based montioring system applied to the failure diagnosis of boiler waterwall.According to the principles of intercommunication pattern
the hardware structure that should be organized for an optimum and minimum instrrmentation system in the light of actual sitration of unit can be elastically designed. Moreover
according to the theory of software engineering
a suit of computer software system
which possesses multifunction like data acquisition & processing
network protocal & on-line monitoring
over-limit alarm & failure analysis and graphic display & report forms printing etc
has been designed. This computer software has many advantages
such as friendly user interface and high portability. This computer monitoring system has been successfully applied to Pingwei Power Plant.