NUMERICAL STUDY OF ADDING BAFFLES IN UTILITY BOILER BURNERS TO PREVENT SLAGGING[J]. Thermal power generation, 1998, (6): 15-17. DOI: 10.19666/j.rlfd.1998.06.005.
电站锅炉燃烧器加挡板防止炉内结渣的数值试验研究
摘要
用计算机辅助优化数值试验 (CAT)方法对某电厂 6 70t/h锅炉进行了CAT优化设计改造
对燃烧器喷嘴加装折向挡板前后炉内切圆直径、气流充满度
炉膛出口扭转残余的变化进行了CAT研究
探讨用燃烧器喷嘴加装折向挡板以解决严重结焦问题。
Abstract
This paper describes a numerical study.with a Computer-Aided-Testing method
on a 670t/h tagential fired boiler with or without baffles in burners
and analyses of imaginarg circle diameters
gas filling factor and residual revolution at the exit from furnace are made so as to find the effect of the baffles in preventing the serious slagging in the boiler.