ABATEMENT OF HIGHER BEARING VIBRATION OF A 125MW UNIT IN ZUNYI POWER PLANT[J]. Thermal power generation, 1998, (3): 35-38. DOI: 10.19666/j.rlfd.1998.03.008.
遵义电厂125MW机轴承振动长期偏大的处理
摘要
本文就遵义电厂 8号机 3号轴承垂直振动长期偏大的原因进行了较为全面的检查、测试和分析
并提出了相应的处理措施
经大修处理后
机组轴承振动达到优良标准。
Abstract
An inspection measurement and analysis were made to find out the causes of higher vertical vibration of bearing №3
unit 8 which had existed for a long time in Zunyi power plant.The reasons are found out and abatment measures are put forward.After their realization in maintenance the bearing vibration was reduced to the required values.