ANALYSIS OF BOILER SUPERHEATER TUBES BURSTINGS IN SHAJIAO B POWER PLANT AND THEIR LIFE ASSESSMENT.[J]. Thermal power generation, 1998, (1). DOI: 10.19666/j.rlfd.1998.01.009.
Abstract This paper studies the attributive character and causes of boiler tube bursting in a power plant.The attributive character of these tube bursting would be the short-term overheating tube burst on the basis of long-term overheating.The burstings attributed to the low speed steam flow inside tubes and the tube material with poor heat resistance for the boiler operation conditions.The results are proved by the kinetic testings for the boiler afterwards.