ANAlYSIS AND COUNTERMEASURES AGAINST OVER - LIMIT SHAFT VIBRATION OF A 300MW TRRBINE GENERATOR UNIT MANUFACTURED WITH FOREIGN INTRODUCED TECHNOLOGY[J]. Thermal power generation, 1997, (2): 45-48.
ANAlYSIS AND COUNTERMEASURES AGAINST OVER - LIMIT SHAFT VIBRATION OF A 300MW TRRBINE GENERATOR UNIT MANUFACTURED WITH FOREIGN INTRODUCED TECHNOLOGY[J]. Thermal power generation, 1997, (2): 45-48. DOI: 10.19666/j.rlfd.1997.02.014.
Over - limit exciter shaft vibration was found in the 300MW tubine generator whiz manufactured with WH technology in Shihong and Hanchuan power plants during their initial period of commissioning
causes were analysed and countermeasures were adopted. With the method of lowering the exciter critical speed to avoid unbalance susceptible zone
this vibration problem was solved and found no more in later units manufactured since then.