DEAERATOR STRUCTURE AND SYSTEM OF 362MW UNIT IN HUANENG YUEYANG POWER STATION[J]. Thermal power generation, 1993, (3): 35-39. DOI: 10.19666/j.rlfd.1993.03.006.
Deaerator structure and system of 362MW unit imported from England GEC in Huancng Yueyang Power Station are described. The steam spray deaerator
the exhaust device to the condenser and the device for pouring cold water to the inlet of boiler feed pump possess remarkable advantages. Some proposals for improving deaerator design are presented.