Binglei Cao, Shuaibing Li, Yi Cui, 等. Terahertz Frequency Domain Response for Insulation State Assessment of Vehicle Cable Terminal Under Electro-Thermal Aging[J]. 中国电机工程学会电力与能源系统学报(英文), 2025,11(1):458-467.
Binglei Cao, Shuaibing Li, Yi Cui, et al. Terahertz Frequency Domain Response for Insulation State Assessment of Vehicle Cable Terminal Under Electro-Thermal Aging[J]. CSEE Journal of Power and Energy Systems, 2025, 11(1): 458-467.
Binglei Cao, Shuaibing Li, Yi Cui, 等. Terahertz Frequency Domain Response for Insulation State Assessment of Vehicle Cable Terminal Under Electro-Thermal Aging[J]. 中国电机工程学会电力与能源系统学报(英文), 2025,11(1):458-467.DOI: 10.17775/CSEEJPES.2023.02300.
Binglei Cao, Shuaibing Li, Yi Cui, et al. Terahertz Frequency Domain Response for Insulation State Assessment of Vehicle Cable Terminal Under Electro-Thermal Aging[J]. CSEE Journal of Power and Energy Systems, 2025, 11(1): 458-467.DOI: 10.17775/CSEEJPES.2023.02300.
Terahertz Frequency Domain Response for Insulation State Assessment of Vehicle Cable Terminal Under Electro-Thermal Aging
摘要
Abstract
To accurately diagnose the aging condition of the vehicle-mounted high-voltage cable terminals under the combined electro-thermal stress
this paper proposes a terahertz frequency spectrum technology-based method. First
an electro-thermal aging platform is established in the laboratory to obtain the test samples of ethylene-propylene rubber (EPR) cable terminals with different aging gradients. Then
the degree of electro-thermal aging is characterized by frequency spectrum
absorption coefficient spectrum
absorption spectrum
refractive index and dielectric constant in the terahertz domain. Moreover
the micro-morphology and micro-area structure of the test samples under different aging gradients are also observed by scanning electron microscopy
and both the material and chemical properties are analyzed. The findings demonstrate that terahertz frequency spectra offer significant benefits in non-destructively detecting and identifying the insulation condition of vehicle cable terminals during electro-thermal aging. Laboratory tests confirm the feasibility of utilizing the terahertz frequency spectrum to assess the insulation aging state of EPR cable terminals
making it potentially applicable for on-site purposes.