Song Xiao, Yifan Wang, Yi Li, 等. Partial Discharge Performance of HFO-1336mzz(E)/CO2: An Eco-Friendly Insulating Gas[J]. 中国电机工程学会电力与能源系统学报(英文), 2026,12(3):1630-1640.
Song Xiao, Yifan Wang, Yi Li, et al. Partial Discharge Performance of HFO-1336mzz(E)/CO2: An Eco-Friendly Insulating Gas[J]. CSEE Journal of Power and Energy Systems, 2026, 12(3): 1630-1640.
Song Xiao, Yifan Wang, Yi Li, 等. Partial Discharge Performance of HFO-1336mzz(E)/CO2: An Eco-Friendly Insulating Gas[J]. 中国电机工程学会电力与能源系统学报(英文), 2026,12(3):1630-1640. DOI: 10.17775/CSEEJPES.2022.04880.
Song Xiao, Yifan Wang, Yi Li, et al. Partial Discharge Performance of HFO-1336mzz(E)/CO2: An Eco-Friendly Insulating Gas[J]. CSEE Journal of Power and Energy Systems, 2026, 12(3): 1630-1640. DOI: 10.17775/CSEEJPES.2022.04880.
Partial Discharge Performance of HFO-1336mzz(E)/CO2: An Eco-Friendly Insulating Gas
摘要
Abstract
HFO-1336mzz(E) (HFO-butene) is regarded as a promising eco-friendly insulating gas to replace sulfur hexafluoride (SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6) used in medium-voltage gas insulated equipment (MV-GIE). In this paper
we systematically explored partial discharge properties of HFO-butene/CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2 gas mixture by revealing partial discharge inception voltage (PDIV)
partial discharge extinction voltage (PDEV)
and phase resolved partial discharge (PRPD) pattern under different mixing ratios
and gas pressure conditions. Meanwhile
the action and influence mechanism of “space charge layer” on PD distribution properties of HFO-butene/CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2 is proposed. We found PDIV of HFO-butene/CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2 demonstrated linear-saturation increase trend with mixing ratio and gas pressure
which is equivalent to that of SF<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6 as HFO-butene content reaches 25%~130%. In addition
there showed “double peak” phenomenon in the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$n-\varphi$ spectrum of HFO-butene/CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2 with low HFO-butene content and gas pressure
which is ascribed to the shielding effect of the stable “space charge layer” nearby the needle electrode that improves non-uniformity of the electric field. Corresponding results revealed PD characteristics of HFO-butene/CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2 gas mixture and brought guidance to development of brought guidance based MV-GIE.
Environment-friendly insulating gases for HVDC gas-insulated transmission lines
Bubble Changing Features and Buckle of the Free Liquid Surface in Active Oiled Power Transformer Tank
Effect of Interface Charge on Partial Discharge Characteristics of Oil-Pressboard Insulation in Non-Uniform AC/DC Combined Electric Field Under Different Temperatures
Stochastic Planning of Integrated Energy System with Low-Grade Heat Based on a Novel Heat Pump Model Considering Multiple Uncertainties
Evolutionary Characteristics of Interfacial Defects Inside Vehicle-Mounted High-Voltage Cable Termination for High-Speed Trains
相关作者
Geng Chen
Youping Tu
Cong Wang
Jue Wang
Zhikang Yuan
Guoming Ma
Jian Wang
Bo Qi
相关机构
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources and the Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University
Institute of Electrical Engineering, Chinese Academy of Sciences
Department of Electrical Engineering, Tsinghua University
Electric Power Research Institute, State Grid Anhui Electric Power Company