Chao Shen, Wei Gu, Wanxing Sheng, 等. Transient Stability Analysis and Design of VSGs with Different DC-Link Voltage Controllers[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(2):593-604.
Chao Shen, Wei Gu, Wanxing Sheng, et al. Transient Stability Analysis and Design of VSGs with Different DC-Link Voltage Controllers[J]. CSEE Journal of Power and Energy Systems, 2024, 10(2): 593-604.
Chao Shen, Wei Gu, Wanxing Sheng, 等. Transient Stability Analysis and Design of VSGs with Different DC-Link Voltage Controllers[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(2):593-604.DOI: 10.17775/CSEEJPES.2022.03300.
Chao Shen, Wei Gu, Wanxing Sheng, et al. Transient Stability Analysis and Design of VSGs with Different DC-Link Voltage Controllers[J]. CSEE Journal of Power and Energy Systems, 2024, 10(2): 593-604.DOI: 10.17775/CSEEJPES.2022.03300.
Transient Stability Analysis and Design of VSGs with Different DC-Link Voltage Controllers
Virtual synchronous control has been widely studied for the advantages of emulating inertia for voltage source converters (VSCs). A constant dc-link voltage is usually assumed in existing literature to estimate transient stability of virtual synchronous generators (VSGs). However
actual power supply in the dc-side of VSGs is limited and different dc-link voltage controllers are needed to achieve power balance between DC side and AC side. Addition of dc-link voltage controller has great influence on transient behavior of VSGs
which has not been investigated by previous research. To fill this gap
this paper gives insights into the effect of dc-link voltage dynamics on transient stability of VSGs. First
two typical kinds of VSGs with dc-link voltage controllers are introduced. Then
mathematical models considering dc-link dynamics are established and the effect of dc-link voltage controllers on transient synchronization stability of VSGs is revealed through equal area criterion (EAC). It is found that dc-link voltage controller would reduce stability margin of VSGs and design-oriented transient stability analysis is carried out quantitively using critical clearing time (CCT). Finally
simulation results are given to validate correctness of theoretical analysis.
Transient Stability Analysis and its Improvement of Isolated Renewable Energy Bases with VSC-DC Transmission
Analytical Stability Criterion and Parameter Tuning of Limited Grid-forming Photovoltaic with DC Voltage Protection
Current Balancing Control Approach for Paralleled MMC Groups in Hybrid LCC/VSC Cascaded HVDC System
Can 100% PLL-Synchronized DFIG-WTs Power Systems Operate Independently?
Design-Oriented Analysis and Enhancement of Transient Power Sharing Between Inverter-Interfaced Generators and Synchronous Generators
相关作者
Ying Huang
Junli Zhang
Guoteng Wang
Zheng Xu
Aolin Jian
Zhen Huang
Lei Chen
Yong Min
相关机构
College of Electric Engineering, Zhejiang University
Department of Electrical Engineering, Tsinghua University
Northeast Branch of State Grid Corporation of China
State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology