Zixuan Guo, Xing Zhang, Fei Li, 等. Double-Machine Equivalent Method for Evaluating Plant- and Unit-Level Stability of Hybrid Grid-Connected Renewable Power Plants[J]. 中国电机工程学会电力与能源系统学报(英文), 2025,11(5):2102-2116.
Zixuan Guo, Xing Zhang, Fei Li, et al. Double-Machine Equivalent Method for Evaluating Plant- and Unit-Level Stability of Hybrid Grid-Connected Renewable Power Plants[J]. CSEE Journal of Power and Energy Systems, 2025, 11(5): 2102-2116.
Zixuan Guo, Xing Zhang, Fei Li, 等. Double-Machine Equivalent Method for Evaluating Plant- and Unit-Level Stability of Hybrid Grid-Connected Renewable Power Plants[J]. 中国电机工程学会电力与能源系统学报(英文), 2025,11(5):2102-2116.DOI: 10.17775/CSEEJPES.2021.08940.
Zixuan Guo, Xing Zhang, Fei Li, et al. Double-Machine Equivalent Method for Evaluating Plant- and Unit-Level Stability of Hybrid Grid-Connected Renewable Power Plants[J]. CSEE Journal of Power and Energy Systems, 2025, 11(5): 2102-2116.DOI: 10.17775/CSEEJPES.2021.08940.
Double-Machine Equivalent Method for Evaluating Plant- and Unit-Level Stability of Hybrid Grid-Connected Renewable Power Plants
Equivalent models are essential for time-domain simulation and harmonic stability evaluation of renewable power plants. Such harmonic instability may co-occur at the plant-level and unit-level
or it may only occur at the unit-level
manifesting as local resonances. However
conventional equivalent methods can only simulate plant-level instability
but cannot consider such unit-level instability. To address this problem
the main contributions of this paper are as follows: 1) Based on the impedance matrix and the eigenvalue analysis
the reason why conventional equivalent methods cannot accurately simulate unit-level stability is studied. 2) A double-machine equivalent method is proposed. The model used in this method is a minimum-scale equivalent model capable of simulating plant-level and unit-level stability
simultaneously. It uses two single-machine models to represent a generation cluster containing
$N$
generation units. A single-machine model
$M_1$
represents
$N-1$
generation units for simplification
while another single-machine model
$M_2$
represents the remaining one gener
ation unit for simulating unit-level stability. 3) Furthermore
a practical improvement approach of the double-machine equivalent method is proposed for taking into account operating point differences and complex connection conditions. Finally
the proposed method is verified by simulations and experiments.
Evolution of Generator Connection Rules for Australian Renewable Energy Transition
Small-Signal Stability Analysis of VSCs with Neative-sequence Current Control Based on LTP and HSS Theory
Stability analysis of multi-paralleled grid-connected inverters including distribution parameter characteristics of transmission lines
Renewable energy transmission by HVDC across the continent: system challenges and opportunities
Transient Stability Analysis of Multiple GFM Converters Connected into an Equivalent Grid from Perspective of Unbalanced Energy
相关作者
Feifei Bai
Ruifeng Yan
Levin Mardira
Jaroslaw Krata
Tapan Kumar Saha
Jiabing Hu
Zeren Guo
Jianhang Zhu
相关机构
School of Electrical Engineering and Computer Science, The University of Queensland
DIgSILENT
EPEC Group
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology
Department of Electrical and Electronic Engineering, The University of Hong Kong