Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems
Regular Papers|更新时间:2026-10-15
|
Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems
Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems
Pallavi Verma, Avdhesh Kumar, Rachana Garg, 等. Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems[J]. 中国电机工程学会电力与能源系统学报(英文), 2023,9(4):1394-1404. DOI: 10.17775/CSEEJPES.2021.07310.
Pallavi Verma, Avdhesh Kumar, Rachana Garg, et al. Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems[J]. CSEE Journal of Power and Energy Systems, 2023, 9(4): 1394-1404. DOI: 10.17775/CSEEJPES.2021.07310.
Pallavi Verma, Avdhesh Kumar, Rachana Garg, 等. Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems[J]. 中国电机工程学会电力与能源系统学报(英文), 2023,9(4):1394-1404. DOI: 10.17775/CSEEJPES.2021.07310.DOI:
Pallavi Verma, Avdhesh Kumar, Rachana Garg, et al. Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems[J]. CSEE Journal of Power and Energy Systems, 2023, 9(4): 1394-1404. DOI: 10.17775/CSEEJPES.2021.07310.DOI:
Continuous Mixed p-norm Control Scheme with Reweighted L0 norm Variable Step Size for Mitigating Power Quality Problems of Grid Coupled Solar PV Systems
the performance of a two-stage three-phase grid coupled solar photovoltaic generating system (SPVGS) is analyzed by using a novel reweighted LO norm variable step size continuous mixed p-norm (RLO-VSSCMPN) of a voltage source inverter (VSI) control scheme. The efficacy of the system is determined by considering unbalanced grid voltage
DC offset
voltage sag and swell
unbalanced load and variations in solar insolation. RL<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0-VSSCMPN is used for inverter control and it extracts fundamental components of load current for generating the reference grid current with a faster convergence rate and lesser steady state oscillations. With the proposed control
harmonics in the grid current follows the IEEE-519 norm and the performance is also satisfactory under varying environmental/load conditions. The power generated from SPVGS is transferred optimally using a DC-DC boost converter utilizing the incremental conductance (INC) maximum power point technique. The proposed system is simulated using MATLAB/Simulink 2018a and test results are verified experimentally using dSPACE1202 in the laboratory to ensure the validity of a novel proposed robust RL<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0-VSSCMPN.