Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates
Regular Papers|更新时间:2026-10-15
|
Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates
Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates
中国电机工程学会电力与能源系统学报(英文)2025年11卷第2期 页码:931-943
作者机构:
1. Xizang Yangbajing High Altitude Electrical Safety and Electromagnetic Environment National Observation and Research Station (China Electric Power Research Institute),Beijing,China
2. State Grid Economic and Technological Research Institute Co. Ltd,Beijing,China
Kun He, Xiaoqian Ma, Li Xie, 等. Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates[J]. 中国电机工程学会电力与能源系统学报(英文), 2025,11(2):931-943.
Kun He, Xiaoqian Ma, Li Xie, et al. Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates[J]. CSEE Journal of Power and Energy Systems, 2025, 11(2): 931-943.
Kun He, Xiaoqian Ma, Li Xie, 等. Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates[J]. 中国电机工程学会电力与能源系统学报(英文), 2025,11(2):931-943.DOI: 10.17775/CSEEJPES.2021.05960.
Kun He, Xiaoqian Ma, Li Xie, et al. Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates[J]. CSEE Journal of Power and Energy Systems, 2025, 11(2): 931-943.DOI: 10.17775/CSEEJPES.2021.05960.
Evaluation of Field-Diffusion Charging Models for Airborne Suspended Particles Charged by Corona Ions: Sum of Charge Quantities and Sum of Charging Rates
摘要
Abstract
To evaluate field-diffusion charging models
a systematic comparative study is conducted in this paper. A field-diffusion charge quantity sum model (FDCQSM) and a field-diffusion charging rate sum model (FDCRSM) are introduced in which the Maxwell-Wagner relaxation model for unipolar field charging is proposed to extend to bipolar charging. The predictions of the two models are compared with the experimental results reported in literature over wide ranges of particle diameters and electric fields. The results show that the FDCQSM is in good consistency with the experiments
while the FDCRSM performs well only if either diffusion charging or field charging dominates. Moreover
the physical meaning of the FDCRSM
the effects of ion property and the particle's conductivity on the particle charge
and applicability of the FDCQSM are discussed. The outcome
in which FDCRSM works badly when field charging and diffusion charging are important
indicates that it is likely to be as factual as FDCQSM. And FDCQSM seems to be valid in the study of the effects of aerosols on the electrical environment around high voltage direct current (HVDC) transmission lines