Yijing Wang, Yangzhen Zhang, Zhiqiang Zuo, 等. State-of-charge Balance Control and Safe Region Analysis for Distributed Energy Storage Systems with Constant Power Loads[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(4):1733-1745.
Yijing Wang, Yangzhen Zhang, Zhiqiang Zuo, et al. State-of-charge Balance Control and Safe Region Analysis for Distributed Energy Storage Systems with Constant Power Loads[J]. CSEE Journal of Power and Energy Systems, 2024, 10(4): 1733-1745.
Yijing Wang, Yangzhen Zhang, Zhiqiang Zuo, 等. State-of-charge Balance Control and Safe Region Analysis for Distributed Energy Storage Systems with Constant Power Loads[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(4):1733-1745.DOI: 10.17775/CSEEJPES.2021.02320.
Yijing Wang, Yangzhen Zhang, Zhiqiang Zuo, et al. State-of-charge Balance Control and Safe Region Analysis for Distributed Energy Storage Systems with Constant Power Loads[J]. CSEE Journal of Power and Energy Systems, 2024, 10(4): 1733-1745.DOI: 10.17775/CSEEJPES.2021.02320.
State-of-charge Balance Control and Safe Region Analysis for Distributed Energy Storage Systems with Constant Power Loads
摘要
Abstract
This paper presents a fully distributed state-of-charge balance control (DSBC) strategy for a distributed energy storage system (DESS). In this framework
each energy storage unit (ESU) processes the state-of-charge (SoC) information from its neighbors locally and adjusts the virtual impedance of the droop controller in real-time to change the current sharing. It is shown that the SoC balance of all ESUs can be achieved. Due to virtual impedance
voltage deviation of the bus occurs inevitably and increases with load power. Meanwhile
widespread of the constant power load (CPL) in the power system may cause instability. To ensure reliable operation of DESS under the proposed DSBC
the concept of the safe region is put forward. Within the safe region
DESS is stable and voltage deviation is acceptable. The boundary conditions of the safe region are derived from the equivalent model of DESS
in which stability is analyzed in terms of modified Brayton-Moser's criterion. Both simulations and hardware experiments verify the accuracy of the safe region and effectiveness of the proposed DSBC strategy.