Shenyang Mo, Xuebao Li, Zhibin Zhao, 等. Discharge Characteristics of Bubbles at Interface Between AlN Ceramic and FC-72 Liquid[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(1):371-380.
Shenyang Mo, Xuebao Li, Zhibin Zhao, et al. Discharge Characteristics of Bubbles at Interface Between AlN Ceramic and FC-72 Liquid[J]. CSEE Journal of Power and Energy Systems, 2024, 10(1): 371-380.
Shenyang Mo, Xuebao Li, Zhibin Zhao, 等. Discharge Characteristics of Bubbles at Interface Between AlN Ceramic and FC-72 Liquid[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(1):371-380.DOI: 10.17775/CSEEJPES.2021.00410.
Shenyang Mo, Xuebao Li, Zhibin Zhao, et al. Discharge Characteristics of Bubbles at Interface Between AlN Ceramic and FC-72 Liquid[J]. CSEE Journal of Power and Energy Systems, 2024, 10(1): 371-380.DOI: 10.17775/CSEEJPES.2021.00410.
Discharge Characteristics of Bubbles at Interface Between AlN Ceramic and FC-72 Liquid
摘要
Abstract
In order to evaluate the insulation of two-phase immersion cooling in the HV power electronic package
the insulation degradation of the dielectric interface induced by bubbles is investigated. In this paper
a test strategy with 50 Hz unipolar DC and AC combined voltage for partial discharge (PD) at boiling interface of AIN ceramic is proposed. The insulation threshold of an AIN ceramic surface is acquired in several dielectric environments
such as air
FC-72 liquid (FC-72
a Fluorinert™ from 3M™)
FC-72 vapor
and boiling state of FC-72. This reveals the deterioration of boiling on the insulation of the surface immersed in the dielectric refrigerant. To investigate the mechanism of the PD feature at the boiling interface
the PD patterns of the unrestricted bubble and the accumulated bubble are acquired and contrastively analyzed. Combined with the feature of the back discharge and the bubble behavior
the charged vapor-ceramic interface is relatively stable due to the accumulated vapor layer. This stability of the charged vapor-ceramic interface is broken if the bubble is unrestricted. Besides
it is discovered that the vapor-liquid interface inside the bubble may be another charged interface
Understanding DC Partial Discharge: Recent Progress, Challenges, and Outlooks
Effect of Interface Charge on Partial Discharge Characteristics of Oil-Pressboard Insulation in Non-Uniform AC/DC Combined Electric Field Under Different Temperatures
Influence of Repetitive Impulse Waveforms on Surface Discharge Characteristics and Insulation Life for Polyimide Film
Enhancement of Soil Discharge Channels on Potential Surrounding Buried Cables Under Impulsive Currents
Evolutionary Characteristics of Interfacial Defects Inside Vehicle-Mounted High-Voltage Cable Termination for High-Speed Trains
相关作者
Chuanyang Li
Tohid Shahsavarian
Mohamadreza Arab Baferani
Kerry Davis
Yang Cao
Di Zhang
Chunjia Gao
Bo Qi
相关机构
Electrical and Computer Engineering, University of Connecticut, Storrs
Naval Postgraduate School, Monterey
China Electric Power Research Institute
Inner Mongolia Electric Economy and Technology Academy
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University