Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers
Regular Papers|更新时间:2026-10-15
|
Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers
Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers
中国电机工程学会电力与能源系统学报(英文)2024年10卷第6期 页码:2350-2359
作者机构:
1. School of Electrical Engineering, Sichuan University,Chengdu,China
2. Electric Power Research Institute, State Grid Gansu Electric Power Co., Ltd.,Lanzhou,China
Wenjuan Du, Zhicheng Ma, Yang Wang, 等. Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(6):2350-2359.
Wenjuan Du, Zhicheng Ma, Yang Wang, et al. Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers[J]. CSEE Journal of Power and Energy Systems, 2024, 10(6): 2350-2359.
Wenjuan Du, Zhicheng Ma, Yang Wang, 等. Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers[J]. 中国电机工程学会电力与能源系统学报(英文), 2024,10(6):2350-2359.DOI: 10.17775/CSEEJPES.2020.02790.
Wenjuan Du, Zhicheng Ma, Yang Wang, et al. Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers[J]. CSEE Journal of Power and Energy Systems, 2024, 10(6): 2350-2359.DOI: 10.17775/CSEEJPES.2020.02790.
Harmonic Oscillations in a Grid-Connected PV Generation Farm Caused by an Increased Number of Parallel-Connected PV Generating Units and Damping Controllers
This paper examines the harmonic oscillations in a grid-connected PV generation farm (PVGF) caused by the parallel connection of an increased number of PV generation units (PVGUs). An equivalent model of the grid-connected PVGF is derived
which clearly explains why there are internal and external oscillation modes in the grid-connected PVGF. An indicator of impedance multiplication (IIM) is proposed to quantitatively estimate the impact of the increased number of PVGUs in parallel connection. The analysis in this paper reveals the mechanism about why the damping of external oscillation modes may decrease when more PVGUs are in parallel connection under the condition that the IIM is positive. An example grid-connected PVGF is presented in this paper to demonstrate and evaluate the derived analysis and conclusions. A method for designing the damping controllers to ensure a negative IIM is proposed. With the damping controllers being installed
the risk of growing harmonic oscillations caused by the increased number of the PVGUs in parallel connection can be effectively eliminated.
关键词
Keywords
references
17. W. K. Dong, W. J. Du, and H F Wang, Research on dynamic equivalent model of a grid-connected wind farm for oscillation stability analysis, [Online ] . in Proceedings of the CSEE , p. 1–14 ( 2020-06-30 ) [ 2020 - 08 - 06 ] . [Online ] . Available: https://doi.org/10.13334/j.0258-8013.pcsee.191942.