Praveen Kumar Bonthagorla, Suresh Mikkili. Performance Investigation of Hybrid and Conventional PV Array Configurations for Grid-connected/Standalone PV Systems[J]. 中国电机工程学会电力与能源系统学报(英文), 2022,8(3):682-695.
Praveen Kumar Bonthagorla, Suresh Mikkili. Performance Investigation of Hybrid and Conventional PV Array Configurations for Grid-connected/Standalone PV Systems[J]. CSEE Journal of Power and Energy Systems, 2022, 8(3): 682-695.
Praveen Kumar Bonthagorla, Suresh Mikkili. Performance Investigation of Hybrid and Conventional PV Array Configurations for Grid-connected/Standalone PV Systems[J]. 中国电机工程学会电力与能源系统学报(英文), 2022,8(3):682-695.DOI: 10.17775/CSEEJPES.2020.02510.
Praveen Kumar Bonthagorla, Suresh Mikkili. Performance Investigation of Hybrid and Conventional PV Array Configurations for Grid-connected/Standalone PV Systems[J]. CSEE Journal of Power and Energy Systems, 2022, 8(3): 682-695.DOI: 10.17775/CSEEJPES.2020.02510.
Performance Investigation of Hybrid and Conventional PV Array Configurations for Grid-connected/Standalone PV Systems
the critical challenge in solar photovoltaic (PV) systems is to make them energy efficient. One of the key factors that can reduce the PV system power output is partial shading conditions (PSCs). The reduction in power output not only depends on a shaded region but also depends on the pattern of shading and physical position of shaded modules in the array. Due to PSCs
mismatch losses are induced between the shaded modules which can cause several peaks in the output power-voltage (P-V) characteristics. The series-parallel (SP)
total-cross-tied (TCT)
bridge-link (BL)
honey-comb (HC)
and triple-tied (TT) configurations are considered as conventional configurations
which are severely affected by PSCs and generate more mismatch power losses along with a greater number of local peaks. To reduce the effect of PSCs
hybrid PV array configurations
such as series-parallel: total-cross-tied (SP-TCT)
bridge-link: total-cross-tied (BL-TCT)
honey-comb: total-cross-tied (HC-TCT) and bridge-link: honey-comb (BL-HC) are proposed. This paper briefly discusses the modeling
simulation and performance evaluation of hybrid and conventional 7 × 7 PV array configurations during different PSCs in a Matlab/Simulink environment. The performance of hybrid and conventional PV configurations are evaluated and compared in terms of global maximum power (GMP)
voltage and currents at GMP
open and short circuit voltage and currents
mismatch power loss (MPL)
fill factor
efficiency
and a number of local maximum power peaks (LMPPs).