Hongshun Liu, Zhitong Xue, Simeng Li, 等. Characteristics of partial discharge in oil-paper insulated needle plate electrode model under composite AC-DC voltage[J]. 中国电机工程学会电力与能源系统学报(英文), 2020,6(4):848-857.
Hongshun Liu, Zhitong Xue, Simeng Li, et al. Characteristics of partial discharge in oil-paper insulated needle plate electrode model under composite AC-DC voltage[J]. CSEE Journal of Power and Energy Systems, 2020, 6(4): 848-857.
Hongshun Liu, Zhitong Xue, Simeng Li, 等. Characteristics of partial discharge in oil-paper insulated needle plate electrode model under composite AC-DC voltage[J]. 中国电机工程学会电力与能源系统学报(英文), 2020,6(4):848-857. DOI: 10.17775/CSEEJPES.2020.01780.
Hongshun Liu, Zhitong Xue, Simeng Li, et al. Characteristics of partial discharge in oil-paper insulated needle plate electrode model under composite AC-DC voltage[J]. CSEE Journal of Power and Energy Systems, 2020, 6(4): 848-857. DOI: 10.17775/CSEEJPES.2020.01780.
Characteristics of partial discharge in oil-paper insulated needle plate electrode model under composite AC-DC voltage
Converter transformers are the core device in ultrahigh voltage direct current (UHVDC) transmission systems
and the oil-paper insulation at its rectifying valve side deals with the composite AC-DC voltage. A detailed investigation of the partial discharge (PD) mechanism in the oil-paper insulation under the composite AC-DC voltage is
therefore
very important. The oilpaper insulated needle plate electrode simulation model for the electric field and charge distribution can be established using hydrodynamic drift-diffusion theory and bipolar charge carrier theory
and the simulation results can reflect the morphological changes of PD. The development characteristics of PD under composite AC-DC voltage are researched. In addition
the effects of simulation time
the AC-DC component proportion
and model parameters on PD are also explored. Results indicate that differences in applied voltage
interface charge
and geometry structure can cause changes in the electric field strength
which consequently influences the PD process in the simulation model. Oil-immersed paperboard is a type of liquid-immersed dielectric (LID). When the LID is arranged in perpendicular
only the positive streamers have narrow channels oriented toward the LID. When the LID is arranged in parallel
the PDs are in the form of creeping discharges and the negative streamers are more dispersed. The development characteristics of PD and its influencing factors reported here may provide theoretical and simulation support to explain the physical mechanism of PD at the rectifying valve side of the converter transformer.
CFD Analysis of an 800 kV HVDC Transformer Using Rapeseed Oil as the Cooling Fluid
Understanding DC Partial Discharge: Recent Progress, Challenges, and Outlooks
Fault diagnosis of power transformers using graph convolutional network
The single-active-part structure of the UHVDC converter transformer with the UHVAC power grid
Failure Rate Prediction of a Power Transformer: A Decomposition-Based Bayesian Deep Learning Method
相关作者
Edgardy M. Gutierrez Diaz
Gaosheng Wei
Liu Cui
Chuanyang Li
Tohid Shahsavarian
Mohamadreza Arab Baferani
Kerry Davis
Yang Cao
相关机构
Department of Power Engineering, School of Electrical Engineering, Bicentenary University of Aragua, Turmero
Key Laboratory of Power Station Energy Transfer Conversion and System (Ministry of Education), School of Energy Power and Mechanical Engineering, North China Electric Power University
Naval Postgraduate School, Monterey
Electrical and Computer Engineering, University of Connecticut, Storrs
North China Electric Power Research Institute Co., Ltd.