M. Tariq Nazir, Faizan Tahir Butt, Haider Hussain, 等. Physical, Thermal and Partial Discharge Evaluation of Nano Alumina Filled Silicone Rubber in an Inclined Plane Test[J]. 中国电机工程学会电力与能源系统学报(英文), 2022,8(4):1242-1249.
M. Tariq Nazir, Faizan Tahir Butt, Haider Hussain, et al. Physical, Thermal and Partial Discharge Evaluation of Nano Alumina Filled Silicone Rubber in an Inclined Plane Test[J]. CSEE Journal of Power and Energy Systems, 2022, 8(4): 1242-1249.
M. Tariq Nazir, Faizan Tahir Butt, Haider Hussain, 等. Physical, Thermal and Partial Discharge Evaluation of Nano Alumina Filled Silicone Rubber in an Inclined Plane Test[J]. 中国电机工程学会电力与能源系统学报(英文), 2022,8(4):1242-1249.DOI: 10.17775/CSEEJPES.2020.01190.
M. Tariq Nazir, Faizan Tahir Butt, Haider Hussain, et al. Physical, Thermal and Partial Discharge Evaluation of Nano Alumina Filled Silicone Rubber in an Inclined Plane Test[J]. CSEE Journal of Power and Energy Systems, 2022, 8(4): 1242-1249.DOI: 10.17775/CSEEJPES.2020.01190.
Physical, Thermal and Partial Discharge Evaluation of Nano Alumina Filled Silicone Rubber in an Inclined Plane Test
摘要
Abstract
Silicone rubber (SiR) composite material is a modern-day insulator for high voltage outdoor applications. The imperfection attributed to SiR is its weak resistance to tracking and erosion when exposed to an outdoor polluted environment which reduces its operational lifetime. This paper investigates the performance of SiR with the addition of 0
1
2.5
5
10 and 20% by weight contents of nano alumina (Al<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3). Inclined plane tests are performed according to IEC 60587 using the step up tracking voltage method with an initial voltage of 3.0 kV and the contaminant solution flow rate is maintained at 0.3 ml/min using a peristaltic pump. The applied voltage level is increased at a rate of 0.25 kV/h. Results suggest that physical tracking
erosion
RMS leakage current and surface partial discharge (PD) performance of samples is improved with the addition of nano alumina. The tracking length
eroded mass
RMS leakage current and average PD magnitude are measured 22%
79%
30% and 52% lesser in 20 wt% relative to 0 wt%
respectively. A thermal distribution analysis is undertaken with infrared camera and it is discovered that heat is accumulated in the discharge area of the liquid flow. The maximum temperature on the insulating specimen is decreased with increasing nanofiller contents. The above promising findings can be due to better thermal stability with low chain mobility at the interaction zone of SiR and alumina. Moreover
less liquid evaporation due to better thermal conduction and improved physical bonding between SiR and nano alumina are possible reasons behind the excellent performance of nanocomposites.