J. H. Zheng, Jun Huang, Shan Deng, 等. Comparison and error analysis of off-design and design models of energy hubs[J]. 中国电机工程学会电力与能源系统学报(英文), 2019,5(4):454-465.
J. H. Zheng, Jun Huang, Shan Deng, et al. Comparison and error analysis of off-design and design models of energy hubs[J]. CSEE Journal of Power and Energy Systems, 2019, 5(4): 454-465.
J. H. Zheng, Jun Huang, Shan Deng, 等. Comparison and error analysis of off-design and design models of energy hubs[J]. 中国电机工程学会电力与能源系统学报(英文), 2019,5(4):454-465. DOI: 10.17775/CSEEJPES.2018.00630.
J. H. Zheng, Jun Huang, Shan Deng, et al. Comparison and error analysis of off-design and design models of energy hubs[J]. CSEE Journal of Power and Energy Systems, 2019, 5(4): 454-465. DOI: 10.17775/CSEEJPES.2018.00630.
Comparison and error analysis of off-design and design models of energy hubs
The accuracy of the simulation model has a profound impact on the optimal operation of the energy hubs (EHs). However
in many articles
the constant model of the efficiency of equipment is adopted to formulate the operation system
which would probably lead to a simplification of the simulation models. But
EHs are typically operated under off-design condition due to the fluctuations in cooling
heating
electricity requirement. Moreover
even though the off-design characteristics are considered
few studies have suggested comparing the differences between those two models by considering the operation cost. In order to assess the effect of the off-design characteristics of EH on the optimal operation accuracy in this paper
two test cases are performed on the fixed and variable load conditions
respectively. In addition
the individual effect of off-design characteristics of each equipment on the optimal operation cost of the EH is also investigated through four optimization runs. It is worth mentioning that the optimal operation problem of the EH considering the off-design characteristics and on-off status of the equipment is a mixed integer non-linear programming problem (MINLP). By testing the design and off-design models on the two cases
the results of simulation demonstrate that the optimal operation cost for the off-design model is larger than that for the design model. Nonetheless
in the aspect of the authenticity of the system operation strategy
the off-design model performs better than the design model. Furthermore
a larger relative error of the system operation cost between the two models can be observed when the EH is operated under a relatively lower load condition
revealing that the influence of off-design characteristic on the optimal operation of EHs is too significant to be neglected.