Guanglu Wu, Jun Liang, Xiaoxin Zhou, 等. Analysis and design of vector control for VSC-HVDC connected to weak grids[J]. 中国电机工程学会电力与能源系统学报(英文), 2017,3(2):115-124.
Guanglu Wu, Jun Liang, Xiaoxin Zhou, et al. Analysis and design of vector control for VSC-HVDC connected to weak grids[J]. CSEE Journal of Power and Energy Systems, 2017, 3(2): 115-124.
Guanglu Wu, Jun Liang, Xiaoxin Zhou, 等. Analysis and design of vector control for VSC-HVDC connected to weak grids[J]. 中国电机工程学会电力与能源系统学报(英文), 2017,3(2):115-124. DOI: 10.17775/CSEEJPES.2017.0015.
Guanglu Wu, Jun Liang, Xiaoxin Zhou, et al. Analysis and design of vector control for VSC-HVDC connected to weak grids[J]. CSEE Journal of Power and Energy Systems, 2017, 3(2): 115-124. DOI: 10.17775/CSEEJPES.2017.0015.
Analysis and design of vector control for VSC-HVDC connected to weak grids
摘要
Abstract
Voltage source converter based high voltage direct current transmission (VSC-HVDC) is considered one of the most suitable technologies to integrate renewable energies. However
connecting VSC to a weak grid is challenging since traditional vector control tends to become unstable under high power demand conditions. In this paper
an improved vector control method is proposed wherein a feed forward branch based on steady state and small signal analysis of the VSC system is added under weak grid situations. The feed forward branch promotes faster reactive power response
thus enhancing the stability of the VSC system. Since the improved vector control uses the same inner loop as traditional vector control
the proposed method allows for the ability to retain fault current suppression capabilities. Furthermore
the control parameters of the outer loop of the improved vector control need not vary according to the variation of the operating points
which makes it easy to implement. The feed forward branch is implemented by solving a nonlinear equation or through use of a look-up table. The influence of the estimation errors of short circuit ratio (SCR) on the control performance is also studied. The effectiveness of the improved vector control is demonstrated through small signal model analysis and time domain simulations.
Dynamic Interaction and Stability Analysis of Grid-following Converter Integrated Into Weak Grid
Voltage Support Capacity Improvement for Wind Farms with Reactive Power Substitution Control
Operating-Point Identification from Dimensions of Alternating Signal Based on Incremental Iterative Mapping Mechanism for Analyzing Dynamics of AC Systems
Asymmetrical Fault Current Calculation Method and Influencing Factors Analysis of Droop-Controlled Inverters
High Frequency Stability Constraints Based MMC Controller Design Using NSGA-III Algorithm
相关作者
Shuang Li
Haijiao Wang
Yuehui Huang
Guoqing He
Chun Liu
Weisheng Wang
Yuegong Li
Guorong Zhu
相关机构
State Key Laboratory of Renewable Energy Grid-Integration, China Electric Power Research Institute
School of Automation, Wuhan University of Technology
State Key Laboratory of Maritime Technology and Safety, Wuhan University of Technology
College of Information Science and Engineering, Wuhan University of Science and Technology