ZENG Zhen, MA Hong-ling, LIANG Xiao-peng, et al. Characterizing deliquescence of surrounding rocks in compressed air energy storage salt caverns and its effects based on the method of cell apoptosis[J]. 2024, 45(12): 3510-3522.
ZENG Zhen, MA Hong-ling, LIANG Xiao-peng, et al. Characterizing deliquescence of surrounding rocks in compressed air energy storage salt caverns and its effects based on the method of cell apoptosis[J]. 2024, 45(12): 3510-3522.DOI: 10.16285/j.rsm.2024.0617.
Salt cavern compressed air energy storage (CAES) is currently an important technique for grid peak regulation using renewable energy sources such as wind and solar power. However
daily gas injection and withdrawal result in high-frequency and high-amplitude fluctuations in the wet environment within the salt cavern. When the cavern temperature drops during gas withdrawal
the relative humidity can reach nearly 100%
causing the surrounding rock salt to deliquesce
which leads to lateral expansion of the cavern and affects its stability and tightness. This study involved exposing damaged rock salt to dry-wet cycles that mimic CAES operation conditions
and measuring the amount of deliquescence. The variation of the deliquescent rate on the salt surface with the deviation stress level was analyzed using the visual morphology
and their fitting relationship was established. A cell apoptosis method for FLAC was developed
which was embedded in the numerical program simulating the long-term deformation of salt caverns. The subroutine calculates the deliquescent amount of the surrounding rock salt cells and induces their apoptosis at appropriate time
to characterize the macroscopic effect of deliquescence on the usability of salt caverns. The results show that after long-term operation
the cavern slightly extends outward due to the deliquescence of the surrounding rock
causing a slight deterioration in the displacements and the safety factor of the cavern wall
but still adequately satisfying the empirical safety criterion. However
deliquescent salt traps moisture in the air
which accumulates at the cavern bottom as brine
significantly reducing the cavern’s available volume. This change is more significant than creep shrinkage and requires control through the use of ground dehumidifiers and regular brine discharging.