ZHOU Hang, YU Hao, ZENG Shao-hua. Experimental study of the installation effect of helical piles in saturated clay on uplift resistance[J]. 2022, 43(12): 3249-3258.
ZHOU Hang, YU Hao, ZENG Shao-hua. Experimental study of the installation effect of helical piles in saturated clay on uplift resistance[J]. 2022, 43(12): 3249-3258.DOI: 10.16285/j.rsm.2022.0137.
Helical piles have received extensive attention in recent years due to its advantages such as convenient construction
load-bearing capacity after installation
and recyclability. However
the previous research was mainly based on the premise of ignoring the installation effect. When the installation effect was considered
researches mainly focused on the degree of disturbance to the relative density of sand. The experimental study of the installation effect in clay is not enough. In response to this problem
a model test was carried out to obtain the load-displacement relationship curves of different types of helical piles. For the helical pile with a single plate
whether the installation effect is considered or not
the variation trends of the ultimate bearing capacity with the increasing of the embedment depth ratio are basically the same
but the ultimate bearing capacity decreases significantly when installation effect is considered. For double-plate pile
after the spacing is greater than 2D
the individual bearing model occurs
and each plate can play its bearing capacity independently. Increasing the number of plates can appropriately improve the bearing capacity
but when the failure model transitions from individual bearing model to cylindrical shear mechanism
the increase of bearing capacity is no longer obvious
and at this moment the critical spacing ratio (S/D)cr is between 1.5 and 2.0. Subsequently
a concept of “disturbance coefficient” is put forward to quantitatively evaluate the reduction of bearing capacity caused by helical pile installation. For the helical pile with a single plate
the disturbance coefficient varies from 0.5 to 0.6 when embedment depth ratio is greater than 4D
and increasing the spacing ratio will lead to an increase in disturbance coefficient ranging from 0.20 to 0.45. For multiple plates